2. Vertical Timing
a. Normal Full Scanning (Settings: Address: 10H, Value: 1XX00XXX; Address: 11H, Value: X000X000)
1 H = 63.5556 µseconds, 29.9700 Hz
1 H = 31.7778 µseconds, 59.9400 Hz
1 H = 21.1852 µseconds, 89.9100 Hz
b. Partial Full Scanning (Settings: Address: 10H, Value: 1XX01XXX; Address: 11H, Value: X000X000)
1 H = 63.5556 µseconds, 31.1569 Hz
1 H = 31.7778 µseconds, 62.3138 Hz
1 H = 21.1852 µseconds, 93.4708 Hz